Professional Fire Extinguisher Service & Maintenance

Compliant with UK regulations. We ensure your fire extinguishers are properly maintained, serviced, and ready for emergencies.

qtq80-ByvjHM (3)

Professional Fire Extinguisher Service & Maintenance

Compliant with UK regulations. We ensure your fire extinguishers are properly maintained, serviced, and ready for emergencies.

Our Services

Comprehensive fire extinguisher services to keep your premises safe and compliant with regulations.

Effective from 1st March 2025, the UK will formally withdraw the remaining national fire safety classification standards (the BS 476 series and BS EN 13501-5 for roofs) in favour of the harmonised BS EN 13501 series. This transition finalises the UK's alignment with the European classification system for the reaction to fire of construction products and roofing materials. The change is intended to create a more consistent approach to fire safety classification across the UK and Europe and to improve the accuracy and reliability of fire performance testing.

Annual Maintenance

Annual Maintenance

Annual inspection of portable fire extinguishers in accordance with BS 5306-3:2020

  • Full visual inspection
  • Pressure gauge check
  • Weight verification
  • Safety seal inspection
  • Comprehensive testing
Extinguisher Refilling

Extinguisher Refilling

Professional refilling and recharging of all extinguisher types.

  • COâ‚‚ recharge service
  • Powder refilling
  • Foam compound replacement
  • Water extinguisher refill
  • Wet chemical replacement
Compliance & Certification

Compliance & Certification

Ensure your premises meet all legal fire safety requirements.

  • Fire risk assessment support
  • Compliance certification
  • Record keeping
  • Regulatory advice
  • Documentation provision

Regulations & Responsibilities

Understanding UK fire safety regulations is essential for compliance and safety.

Legal Requirements

Legal Requirements

Under the Regulatory Reform (Fire Safety) Order 2005

(RRO/FSO), the Responsible Person must:

  • Provide appropriate firefighting equipment
  • Ensure equipment is maintained in good working order
  • Carry out regular fire risk assessments
  • Keep records of all maintenance and testing
  • Ensure staff are trained in equipment use
Responsibilities

Responsibilities

The "Responsible Person" (employer, building owner, or occupier) has specific duties:

  • Appoint competent persons to assist with fire safety
  • Provide suitable fire extinguishers for the risks present
  • Ensure extinguishers are correctly located and accessible
  • Arrange for regular maintenance by competent persons
  • Keep maintenance records for inspection by authorities
Standards & Compliance

Standards & Compliance

Fire extinguishers must comply with British Standards:

  • BS 5306-3:2017 - Fire extinguisher maintenance
  • BS 5306-8:2023 - Selection, positioning, and commissioning

  • BS EN 3-7:2004+A1:2007 - Portable extinguisher characteristics and performance

  • All maintenance and commissioning work must be carried out by a UKAS-accredited third-party certificated organisation (e.g., BAFE SP101 or equivalent) to demonstrate compliance with Article 17 of the Regulatory Reform (Fire Safety) Order 2005.

Fire Extinguisher Types

Different fires require different types of extinguishers. We service all types according to BS standards.

Water

For wood, paper, textile, and solid material fires. Not suitable for electrical or flammable liquid fires.
Color Code: Red

Foam

For solid materials and flammable liquids. Forms a sealing film over liquids to prevent re-ignition.
Color Code: Cream

Dry Powder

Versatile for various fires including electrical. Can be messy and reduce visibility.
Color Code: Blue

COâ‚‚

For flammable liquids and electrical fires. Leaves no residue, safe for electrical equipment.
Color Code: Black

Wet Chemical

Specifically for cooking oil and fat fires (kitchen fires). Creates a soaplike layer to prevent re-ignition.
Color Code: Yellow

Dry Powder

Designed for fires involving combustible metals. Use specialized dry powders. Can be harmful to sensitive equipment.
Color Code: Signal Violet

Maintenance Schedule

Regular maintenance is essential to ensure extinguishers function properly in an emergency.

Maintenance Requirements

Maintenance Requirements

Monthly Visual Check
Quick inspection by responsible person to ensure extinguisher is in place, unobstructed, seal intact, and pressure gauge shows correct pressure.

Annual Inspection
Annual inspection of portable fire extinguishers in accordance with BS 5306-3:2020.

Extended Service
Five-yearly extended service of portable fire extinguishers in accordance with BS 5306-3:2020.

Overhaul / Replacement
Every 10 years for COâ‚‚ extinguishers (hydrostatic pressure test). Most extinguishers require replacement after 20 years.

Key Maintenance Points

Key Maintenance Points

Competent Personnel: All maintenance must be carried out by trained, competent persons

Record Keeping: Detailed service records must be kept for inspection

Immediate Replacement: Any damaged or used extinguisher must be replaced immediately

Correct Positioning: Extinguishers must be properly mounted with clear signage

Safety First
Never attempt to service fire extinguishers without proper training. Incorrect maintenance can render extinguishers dangerous or ineffective in an emergency.

Contact Us

Get in touch for professional fire extinguisher services, maintenance, and compliance advice.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Service Request Form